For Research Use Only — Not for Diagnostic Procedures

Mag Pro-32: Automated Nucleic Acid Extraction for 32 Samples

32 samples in 15–40 minutes. Walk-away protocol. Validated for LAMP and PCR workflows (manufacturer-stated).

check_circle 32 Samples Per Run check_circle Built-In UV Decontamination check_circle LAMP-Validated Kits
Mag Pro-32 automated nucleic acid extraction instrument
verified_user

Validated Performance

LAMP, PCR & RT-PCR workflows (manufacturer-stated)

biotech 32 Samples Per Run
clean_hands Built-In UV Decontamination
science LAMP-Validated Kits
security Research Use Only

Streamlined Workflow

Automated extraction in three simple steps — designed for research lab efficiency.

01
inventory_2

Load Samples

Add up to 32 samples to a compatible pre-loaded reagent plate according to the kit procedure, then load the plate into the instrument.

02
settings_input_component

Select Protocol

Choose from pre-loaded protocols on the tablet touchscreen — select your sample type and press start.

03
directions_walk

Walk Away

The Mag Pro-32 handles binding, wash, and elution automatically — then runs its UV decontamination cycle. Completes in 15–40 minutes (manufacturer-stated).

Why Labs Choose the Mag Pro-32

32 Samples / Run

Process Your Entire Batch Simultaneously

Handles up to 32 samples in one automated run — no batching, no serial processing, no waiting.

UV Decontamination

Built-In UV Lamp Runs After Every Batch

A built-in UV lamp supports post-run decontamination. Follow the current operator manual and your laboratory SOP for cleaning between batches.

Validated Workflows

LAMP, Real-Time PCR, and RT-PCR

With PLM-2007 kits, validated for three downstream molecular applications (manufacturer-stated).

Customizable

Flexible Protocols via Tablet Interface

Multiple built-in purification procedures selectable from a tablet — configure for your sample type without a service call.

Designed for Your Role

Automate 32-Sample Extractions in 15–40 Minutes — Reclaim Bench Time Without a Six-Figure Platform

Your lab's molecular workflow runs on extraction purity. Manual magnetic bead protocols become harder to standardize as volume and staffing change. The Mag Pro-32 automates defined extraction steps: load up to 32 samples, select a protocol, and start the run. LAMP, real-time PCR, and RT-PCR compatibility is manufacturer-stated.

  • check_circle32 samples per run, 15–40 minutes — replaces hours of manual bench time (operator-dependent)
  • check_circleBuilt-in UV lamp — cross-batch contamination control built in, not bolted on
  • check_circleValidated for LAMP, PCR, and RT-PCR — three downstream applications (manufacturer-stated)

Standardize Defined Extraction Steps Across Your Team

The Mag Pro-32 uses selectable purification procedures and automated movement through binding, wash, and elution steps. This can reduce operator-dependent variation when the same validated protocol and laboratory controls are used.

  • check_circleAutomated steps can reduce operator-dependent variation
  • check_circlePre-loaded reagent plates reduce pipetting steps and preparation errors
  • check_circleTablet interface with selectable protocols — minimal training required

Load 32 Samples, Press Start — Free Your Hands for Work That Matters

The Mag Pro-32 automates binding, wash, and elution steps using compatible reagent plates. Its built-in UV lamp supports the laboratory's post-run decontamination procedure. LAMP, PCR, and RT-PCR compatibility is manufacturer-stated.

  • check_circle32 samples per automated run, 15–40 minutes (manufacturer-stated)
  • check_circlePre-loaded reagent plates reduce manual pipetting steps
  • check_circleProtective probes reduce cross-batch contamination — standard on every run

People Also Purchased

Extraction kits used with the Mag Pro-32 workflow. Confirm current compatibility, availability, and labeling before purchase.

biotech PLM-2007
RNA Extraction

Mag Pro Plus Automated RNA Extraction Kit

Pre-loaded 32T extraction plates designed for the Mag Pro-32 — validated for LAMP, real-time PCR, and RT-PCR (manufacturer-stated).

coronavirus PLM-2009-32T
Virus DNA/RNA

Mag Pro Virus DNA/RNA Extraction Kit

96-well deep well plate format for viral nucleic acid extraction — compatible with the Mag Pro-32 instrument.

science PLM-2000
RNA Extraction

Pro-Mag™ RNA Extraction Kit

100-preparation RNA extraction kit using silica-coated magnetic beads; downstream compatibility is manufacturer-stated.

View Product

Technical Specifications

Specification Value
Catalog NumberPLM-NPA-32
Product TypeAutomated Nucleic Acid Extraction Instrument
RUO DesignationFor Research Use Only — Not for Diagnostic Procedures
Sample Throughput1–32 samples per run
Extraction Time15–40 minutes (protocol-dependent)
Sample Volume Range20–1,000 µL
Magnetic Bead Efficiency>98% (manufacturer-stated)
InterfaceTablet touchscreen
UV SterilizationBuilt-in UV lamp
Heating ModuleYes (lysis and elution)
Protective ProbesYes
Dimensions (L×W×H)~430 × 395 × 435 mm*
Weight~32.5 kg*
Compatible KitsPLM-2007, PLM-2009-32T, PLM-2000
Downstream ApplicationsLAMP, Real-Time PCR, RT-PCR

*Dimensions and weight from OEM reference specification — confirm with Pro-Lab Direct for shipped specifications.

Frequently Asked Questions

The Mag Pro-32 processes up to 32 samples simultaneously in a single automated run. Smaller batches (1–31 samples) can also be processed using the same procedure.
A typical extraction run takes 15–40 minutes for up to 32 samples (manufacturer-stated). Exact time varies by protocol and sample type.
The Mag Pro-32 is compatible with PLM-2007 (Mag Pro Plus Automated RNA Extraction Kit), PLM-2009-32T (Mag Pro Virus DNA/RNA Extraction Kit), and PLM-2000 (Pro-Mag RNA Extraction Kit). Contact Pro-Lab Direct to confirm compatibility with other extraction kits.
The instrument itself does not require cold chain — it ships as standard freight. Compatible extraction kits should be stored per their individual product specifications.
Yes — when used with the PLM-2007 Mag Pro Plus Automated RNA Extraction Kit, the Mag Pro-32 is validated for LAMP (loop-mediated isothermal amplification) downstream applications, as well as real-time PCR and RT-PCR (manufacturer-stated).
Manual magnetic bead extraction for 32 samples typically requires 2–3 hours of hands-on bench time (operator-dependent). The Mag Pro-32 automates binding, wash, and elution — processing 32 samples in 15–40 minutes (manufacturer-stated). The instrument also includes built-in UV decontamination and protective probes to reduce carryover contamination.
Yes — PLM-NPA-32 is sold through Pro-Lab Direct, Pro-Lab's US distribution operation based in Georgetown, TX. Contact us via the quote request form or call (512) 832-9145.
Pro-Lab currently offers the Mag Pro-32 for research workflows, not diagnostic procedures. Review the current instrument and compatible-kit labeling before use, and contact Pro-Lab Direct with application questions.

Ready to Automate Your Extraction Workflow?

request_quote

Request a Quote

Request current instrument pricing, availability, and lead-time information.

co_present

Book a Demo

20-min instrument and kit walkthrough — virtual or on-site.

shopping_cart

Request Kit Pricing

Confirm compatible kit selection, pricing, and current availability.

support_agent

Talk to a Specialist

Applications support · (512) 832-9145

For Research Use Only — Not for Use in Diagnostic Procedures. Pro-Lab currently offers the Mag Pro-32 (PLM-NPA-32) for research workflows, not diagnostic procedures. Use compatible extraction kits according to their current labeling. Technical specifications marked with * are from OEM reference documentation — confirm with Pro-Lab Direct prior to purchase. The >98% magnetic bead collection efficiency is manufacturer-stated (OEM specification).