Pro-Lab Direct · Pro-Safe Biosafety Cabinets & Fume Hoods

Pro-Safe BSC & fume hood — pricing, spec sheets, NSF/ANSI 49 certification documentation

Below is the published price list, model spec summary, and NSF/ANSI 49-2024 certification reference for Pro-Safe biosafety cabinets and fume hoods. All prices are listed online — no quote required for standard models. Free shipping is included.

Published price list

ModelSKUWidthDirect price
Class I BSCPLS100-series3 ftFrom $3,309.50
Class II A2 BSCPLS150 (2 ft)2 ftFrom $5,961.22
Class II A2 — NSF/ANSI 49-2024 certifiedPLS1523 ft$7,571.45
Class II A2 — NSF/ANSI 49-2024 certifiedPLS1534 ftPer published catalog
Class II A2 — NSF/ANSI 49-2024 certifiedPLS1546 ftPer published catalog
Class II B2 BSC (full external exhaust)PLS200-series3–6 ftFrom $7,699 to $10,288
Class III glove-box BSCPLS300-seriesFrom $19,521
Chemical Fume HoodPLS4014 ft$4,155.87
Chemical Fume HoodPLS400-series3.3–6 ft$4,019–$5,518
Laminar flow clean benchPLS500-seriesFrom $2,671

Free shipping on every unit. Lead time: Class I/II BSC 5–7 weeks; laminar flow 6–8 weeks; fume hoods — contact for current availability.

NSF/ANSI 49-2024 certification — what it covers

  • Awarded after 13 physical and biological challenge tests by an independent NSF-accredited testing body.
  • Same credential carried by Labconco and Thermo Fisher Class II A2 cabinets.
  • Required by most institutional purchasing policies (universities, hospitals, government, pharma) and for BSL-3 work per CDC/NIH BMBL 6th Edition.
  • Annual field recertification required (typically $125–$150 per unit per year, by an NSF-accredited certifier).
  • Pro-Safe NSF-certified models: PLS152 (3 ft), PLS153 (4 ft), PLS154 (6 ft).

Class II A2 ductwork — the cost most labs miss

All Pro-Safe Class II A2 cabinets (PLS150–PLS204, including the NSF-certified PLS152/153/154) operate without external ductwork — 70% air recirculation through internal HEPA filters, 30% HEPA-filtered exhaust to the room. Only Class II B2 and Class III cabinets require dedicated external exhaust ductwork. This typically saves $2,000–$8,000 in installation costs vs. a B2 specification.

Documentation package available on request

  • ISO 13485:2016 manufacturer certificate (NQA ANAB-accredited)
  • NSF/ANSI 49-2024 certification (PLS152/153/154)
  • ASHRAE 110 test report (fume hood models — per request, by SKU)
  • Electrical safety listing
  • HEPA filter certificate, factory leak-test record
  • OSHA 29 CFR 1910.1030 compliance reference summary
  • Formal written quote on company letterhead within 1 business day for institutional bid thresholds

Three-quote workflow for purchasing

University and hospital purchasing offices that require three competitive quotes can generate Pro-Safe documentation directly from the published product page — no account login, no sales rep call, no quote-cycle delay. For orders above your institutional bid threshold we issue a formal written quote on company letterhead within one business day.

Reply with model + quantity for a same-day formal quote, or with your institutional bid threshold and we will preempt the paperwork.