Pro-Lab Direct · Pro-Cool -86°C ULT Freezers

Pro-Cool ULT Freezer — IQ/OQ/PQ checklist, energy comparison, sizing guide

Below is the spec sheet you requested. The IQ/OQ/PQ documentation checklist confirms what you receive in the validation packet that ships with every Pro-Cool unit; the energy table compares 10-year electricity cost vs. older Revco/Forma designs; the sizing guide maps blood bank, research, and core-lab use cases to PLF186C2 through PLF186C30.

1. IQ/OQ/PQ Documentation Checklist (included as standard)

Installation Qualification (IQ) protocol — receipt verification, utility connection record, calibration certificateIncluded
Operational Qualification (OQ) protocol — temperature uniformity at 5 points, pull-down to −86°C, alarm function testIncluded
Performance Qualification (PQ) protocol — 24-hour temperature stability, recovery from 30-second door openIncluded
NIST-traceable calibration certificate (factory, pre-ship)Included
Manufacturer ISO 13485:2016 quality system certificateIncluded
Equivalent third-party qualification through Thermo Fisher / EppendorfTypically $3,500–$5,000 add-on

2. Energy Comparison — 10-year operating cost

Freezer classkWh/day10-yr cost @ $0.14/kWh
Pro-Cool (R290/R170 cascade)10–14$5,110–$7,154
Older Revco / Forma (HFC, single-stage compressor service age)18–22$9,198–$11,242
Net 10-year savings vs. older HFC designs: approximately $4,000–$6,000 per unit.

3. Model Sizing Guide

ModelVolumeBest fit
PLF186C22.0 cu.ft (56 L)Small QC archive, single-PI bench — fits under bench
PLF186C666.6 cu.ftReference lab QC strain library, satellite blood bank
PLF186C1212 cu.ftMid-size hospital blood bank FFP storage
PLF186C2020 cu.ftCore lab biorepository — ~12,000 vials in standard racks
PLF186C2424 cu.ftLarge hospital blood bank, multi-PI shared core
PLF186C3030 cu.ftHigh-volume biorepository — ~18,000 vials in standard racks

Specifications — all models

  • Temperature range: −40°C to −86°C
  • Cascade dual-compressor refrigeration (R290 + R170 natural hydrocarbons; zero ODP, near-zero GWP)
  • Audible/visual high-temp alarm, door-ajar alarm, dry-contact relay output for BMS
  • 2-year parts & labor warranty
  • ISO 13485:2016 manufactured
  • PLF186C2 ships from US inventory; larger models 2–4 weeks lead time from domestic warehouse

Want a quote on multi-unit pricing or a comparison sheet against Thermo TSX/Forma 89000? Reply to this email and we will respond same business day.